The Contact Problem In The Pullout Analysis Of An Anchor Bolt Embedded In Concrete
Price
Free (open access)
Transaction
Volume
19
Pages
8
Published
1997
Size
557 kb
Paper DOI
10.2495/BE970091
Copyright
WIT Press
Author(s)
A.L. Saleh and M.H. Aliabadi
Abstract
This paper presented the contact problem of two bodies, i.e. anchor bolt and concrete, which are in contact over a certain region. In the pullout analysis, it is assumed that the concrete is only in contact with the upper edge of the anchor head where large compressive stresses occur. The crack in concrete is analysed using the boundary element method together with the fictitious crack model to represent the fracture process zone in concrete. The numerical results obtained are compared with the round-robin analysis of pullout test proposed by RILEM TC 90-FMA. 1 Introduction The contact analysis in the case of the pullout test is an analysis of tw
Keywords