The Performance Of A Selector To Solve Bulkmg Sludge Problem In An Activated Sludge Process
Price
Free (open access)
Transaction
Volume
49
Pages
8
Published
2001
Size
566 kb
Paper DOI
10.2495/WP010161
Copyright
WIT Press
Author(s)
A. Mohseni-Bandpi & Z. Yousefi
Abstract
The performance of selector to solving bulking sludge problem in activated sludge process A. Mohseni-Bandpi & Z. Yousefi Department of Environmental Health Engineering, Health Faculty, Sari, Iran. Abstract An investigation was carried out to evaluate the performance of selector in activated sludge under extended aeration mode to control bulking sludge problem. The first phase of this study a bench scale of extended aeration process without a selector was run to evaluate the possible formation of bulking sludge. The results of this part show that SVI value was 200-600 ml/g. After using hydrochloride powder as a chemical material for controlling bulking sludge problem, the SVI reduced to 50 to 80 ml/g. After installing a selector zone this value was corrected to 80 to 120 ml/g. The second phase of this research, a pilot scale extended aeration process was designed and constructed with plastic material and a selector was installed in head of aeration unit. The characteristics of
Keywords