Modified Thermal Calculations Of A Geothermal Double-pipe Heat Exchanger With Insulation Immersed Into Geothermal Deposit
Price
Free (open access)
Transaction
Volume
27
Pages
10
Published
2000
Size
242 kb
Paper DOI
10.2495/HT000431
Copyright
WIT Press
Author(s)
T. Kujawa & W. Nowak
Abstract
Kujawa, Nowak and Szaflik [3,4] presented an approximate analytical method of calculation for the Field exchanger with insulated top part with intermediate fluid. In this work the authors modified the method of calculations for the Field exchanger. In this method a boundary condition assuming equal temperatures at the turning point was calculated during determining integration constants. That allows one to get an analytical relation, which enables to directly determine the temperature field of fluid in the heat exchanger. That operation simplified the calculations of output heat and cut down the time of the calculations. The authors also analysed the influence of main parameters on the temperature field as well as on an output heat flow by intermediate fluid in a
Keywords