An Approach To Assess And Manage The Risk Of An Urban LPG Station In Korea
Price
Free (open access)
Transaction
Volume
72
Pages
9
Published
2004
Size
370 kb
Paper DOI
10.2495/SC040541
Copyright
WIT Press
Author(s)
K.S. Park & Y.D. Jo
Abstract
An approach to assess and manage the risk of K.-S. Park & Y.-D. Jo Institute of Gas Safety Technology, Korea Gas Safety Corp., S. Korea Abstract The risk of an LPG filling station has been assessed and risk-reducing measures have been suggested. Hazards of the LPG station are identified through the ETA (Event tree analysis). Consequence analysis is conducted for 3 cases of equivalent leaking diameters in terms of the jet fire, pool fire, VCE (Vapor cloud explosion), and BLEVE (Boiling liquid expanding vapor explosion). Frequency analysis is conducted for the given facility and then further recommendations have been given. Keywords: LPG filling station, event tree analysis, jet fire, pool fire, VCE, BLEVE, frequency analysis. 1 Introduction Since the early 1960s when liquefied petroleum gas (LPG) was first introduced in Korea, the consumption of LPG has been increasing constantly and playing an important role as clean, convenient and environmentally friendly field in both industrial and reside
Keywords