WIT Press


Assessing The Effectiveness Of Air-bubble Plume Aeration In Reducing Evaporation From Farm Dams In Australia Using Modelling

Price

Free (open access)

Volume

145

Pages

12

Page Range

485 - 496

Published

2011

Size

1,227 kb

Paper DOI

10.2495/WRM110421

Copyright

WIT Press

Author(s)

F. Helfer, C. Lemckert & H. Zhang

Abstract

This paper aims to assess the effectiveness of artificial destratification by airbubble plumes in reducing evaporation from farm dams in Australia. A onedimensional model was applied to simulate the change in water temperature and evaporation rates of a real farm dam in Queensland under aeration conditions. Results show that destratification systems can reduce surface temperature, but the highest reduction in evaporation for the studied reservoir would be only 2.5%. The main conclusion is that it is unlikely that the technique will be feasible for small farm dams, given the high costs involved with the operation of an aeration system and the small quantity of water saved through evaporation reduction. The results also indicate that the technique may be effective for reservoirs that experience long periods of accentuated thermal stratification, such as large, deep dams, in which the mixing process would lead to higher reductions in surface temperature and, consequently, in evaporation rates. Keywords: DYRESM, thermal stratification, water aeration, evaporation, water temperature, destratification. 1 Introduction Australian farm dams’ capacity is approximately 7000 GL (7 x 109 m3), representing 9% of the total water stored across the country. It is estimated however that 40% of the volume stored is lost every year due to the high rates of evaporation in agricultural areas in New South Wales and Queensland (Craig et al. [1]). Extremely high radiation and air vapour deficits make these areas experience evaporation rates that can surpass 2000 mm per year. As a

Keywords

DYRESM, thermal stratification, water aeration, evaporation, water temperature, destratification