WIT Press


Comparison Of Conventional And Hybrid Modulus Press-fit Proximal Femoral Prostheses

Price

Free (open access)

Volume

3

Pages

13

Published

1996

Size

1,348 kb

Paper DOI

10.2495/BSIM960121

Copyright

WIT Press

Author(s)

J.A.O. Simoes & M. Taylor

Abstract

The aim of the this study was to compare the load transfer mechanisms of a standard press-fit proximal femoral prosthesis fabricated from three conventional implant materials, cobalt- chrome, titanium and an 'isoelastic' material with that produced by a hybrid modulus prosthesis using the finite element method In particular, both the periosteal and the endosteal bone stresses were examined. Comparison of the results from the three conventional implant materials were similar to those reported in the literature, with the isoelastic prosthesis producing the least stress shielding of the proximal medial femur and the stiffer implant materials producing low proximal medial interface pressures and cancellous bone stress distribu

Keywords